G1000 System Maintenance Manual – Diamond DA40/40F Page 3-39
190-00545-01 Revision G
3.5.12 Enhanced Search and Rescue (SAR) Reactivation
If the Enhanced SAR option was previously enabled and the G1000 was reconfigured (default GROUP
configuration file was loaded), it is necessary to reactivate Enhanced SAR.
Perform this procedure to reactivate Enhanced SAR.
NOTE
When the Enhanced SAR option is enabled for the first time (normally at the Diamond
factory), the G1000 writes its unique system ID to the physical card and locks the files to
this unique ID. This prevents the unlock card from ever being used to activate the
Enhanced SAR feature in other G1000 systems. The unlock card is forever tied to the
specific aircraft in which it was used for the first time. For situations where Enhanced
SAR must be re-activated, this card must be used. Reference section 1.6 and the
applicable General Arrangement Drawing for Unlock card details.
1. Remove power from the PFD and MFD by opening the PFD and MFD circuit breakers.
2. A special Enhanced SAR Unlock Card is required to activate this feature. Refer to the
appropriate General Arrangement drawing for the correct part number. Insert this card in the
upper slot of the PFD.
3. While holding the ENT key on the PFD and MFD, restore power to both displays by closing the
PFD and MFD circuit breakers.
4. When the words appear in the upper left corner of the displays,
release the ENT key.
5. On the PFD, go to the System Upload page using the FMS knob.
6. Activate the cursor. Use the small FMS knob to select ENHANCED SAR in the GROUP field
and press the ENT key.
7. Highlight the ITEM field. Use the small FMS knob to select the “Enhanced Search and Rescue”
option and press the ENT key. Once the option is selected the configuration files in the
PRODUCT field will be displayed. All files should be checked. If not, press the CHK ALL
softkey.
8. Press the LOAD softkey.
9. Monitor the status of the upload. When the upload is finished, press the ENT key to acknowledge
the upload complete confirmation.
10. View the SUMMARY field and ensure that the item is ‘COMPLETE’.
11. De-activate the cursor.
12. Power down the system and remove the Enhanced SAR Unlock Card from the PFD.
Seitenansicht 82