G1000 System Maintenance Manual – Diamond DA40/40F Page 2-17
190-00545-01 Revision G
2.8 Shield Block Grounds
Most G1000 connectors employ a Shield Block grounding system to provide necessary ground reference
to wire shielding and/or transducers. The shield block termination method allows multiple grounds to be
terminated directly to a block mounted to the connector backshell assembly. Refer to G1000/DA40
Install Drawing, 005-00304-00 for installation details. Note that pre-2008 G1000 installations may
employ a slightly different shield grounding system called a “SPIDER” system. Note that aircraft
changing from a FAA certification to an EASA certification will require changing the SPIDER grounding
system to the shield block method.
2.9 Sensor Installations
Refer to 005-00304-00, Sheets 5, 9, & 12 for the engine sensor installation drawings.
2.10 Block Diagrams
2.10.1 G1000 & KAP140
Figure 2-6. G1000/KAP 140 Block Diagram (no WAAS)