Page 5-36 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
Table 5-20 GIA1 RS-232 (Cont)
Channel LRU Indicator Status
CHNL 6 GRS 77 #1
GIA1/GRS 77 data path is functioning correctly.
GIA1/GRS 77 data path is not functioning correctly:
• Reconfigure GIA1.
• Reconfigure GRS 77.
• Check the GIA1/GRS 77 interconnect for wiring
faults.
• Swap the GIA’s to confirm if the problem is in the
original GIA.
o Replace original GIA if box turns green after
swapping units.
o Replace GRS 77 if problem remains.
GIA1/GRS 77 data path functionality is unknown. Reload
GIA1 configuration file.
CHNL 7
GMA
1347 #1
GIA1/GMA 1347 data path is functioning correctly.
GIA1/GMA 1347 data path is not functioning correctly:
• Reconfigure GIA1.
• Reconfigure GMA 1347.
• Check the GIA1/GMA 1347 interconnect for wiring
faults.
• Swap the GIA’s to confirm if the problem is in the
original GIA.
o Replace original GIA if box turns green after
swapping units.
o Replace GMA 1347 if problem remains.
GIA1/GMA 1347 data path functionality is unknown. Reload
GIA1 configuration file.