Page 4-32 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
4. Power the MFD on in configuration mode by holding down the ENT key while applying power
(release the ENT key when the words “INITIALIZING SYSTEM” appear on the display).
NOTE
Loading “GDU Backup Cap Test Software (006-B0380-15)” to the GDU may present the following
nuisance messages on the MFD and PFD screens while loading. Acknowledge the message by
pressing the ENT key or let it time out to move to the next step.
a) “Splash Screen File not Found”.
b) “Unknown Configuration for Config Module” – xxxxxxxxxxxx (denotes place holder
for the specific configuration listed.
5. Press the ENT key at the “DO YOU WANT TO UPDATE SYSTEM FILES?” prompt.
6. Press the ENT key to confirm software update completion.
7. Remove the SD card from the MFD and insert into the top slot of the PFD (leave the MFD on in
configuration mode).
8. Power the PFD on in configuration mode by holding down the ENT key while applying power
(release the ENT key when the words “INITIALIZING SYSTEM” appear on the display).
9. Press the ENT key at the “DO YOU WANT TO UPDATE SYSTEM FILES?” prompt.
10. Press the ENT key to confirm software update completion.
11. Use the FMS knob to select the SYSTEM UPLOAD Page.
12. Select the configuration file “Backup Capacitor Test 50ms” from the SYSTEM UPLOAD Page
(
Figure 4-14).
Figure 4-14. Backup Capacitor Test Selection