G1000 System Maintenance Manual – Diamond DA40/40F Page 5-51
190-00545-01 Revision G
5.10 GIA Alert Messages
5.10.1 COM Alerts
Table 5-37. COM Alerts
Failure Message Cause Solutions
COM1 SERVICE – COM1 needs
service. Return unit for repair.
The system has determined
COM1 needs service.
Replace GIA1 according to instructions in
Section 6.
COM2 SERVICE – COM2 needs
service. Return unit for repair.
The system has determined
COM2 needs service.
Replace GIA2 according to instructions in
Section 6.
COM1 PTT – COM1 push-to-talk
key is stuck.
The COM1 external push-to-talk
(PTT) switch is stuck in the
enabled (or “pressed”) state.
Press the push-to-talk switch(s) again to
cycle its operation.
Check push-to-talk switch(s) and wiring.
Check GIA1/GMA 1347 interconnect.
Switch GIA1 and GIA2, to identify
whether the unit or connectors/wiring is
at fault (Both GIAs must be configured
when swapped; see Section 3.5):
9 If problem follows the unit,
replace GIA1.
9 If problem persists replace
defective GMA 1347.
COM2 PTT – COM2 push-to-talk
key is stuck.
The COM2 external push-to-talk
(PTT) switch is stuck in the
enabled (or “pressed”) state.
Press the push-to-talk switch(s) again to
cycle its operation.
Check push-to-talk switch(s) and wiring.
Check GIA2/GMA 1347 interconnect.
Switch GIA1 and GIA2, to identify
whether the unit or connectors/wiring is
at fault (Both GIAs must be configured
when swapped, see Section 3.5):
9 If problem follows the unit,
replace GIA2.
9 If problem persists replace
defective GMA 1347.
COM1 RMT XFR – COM1 remote
transfer key is stuck.
The COM1 external remote
transfer switch is stuck in the
enabled (or “pressed”) state.
Press the COM1 external remote transfer
switch again to cycle its operation.
Check COM1 external remote transfer
switch and wiring.
Switch GIA1 and GIA2, to identify
whether the unit or connectors/wiring is
at fault (Both GIAs must be configured
when swapped, see Section 3.5)
9 If problem follows the unit,
replace GIA1.
9 If problem persists, continue to
troubleshoot remote transfer
switch & wiring.