Page 5-2 G1000 System Maintenance Manual - Hawker Beechcraft G36
Rev. 5 190-01259-00
Table 5.2 – SVS Alert Messages
Failure Message Cause Solution
SVS – SVS DISABLED: Out of
available terrain region.
SVS is disabled because the
aircraft exceeded the
boundaries of the loaded terrain
database.
Geographical operation limitations
are defined in the SVS/Pathways
AFMS, which is referenced in Table
1.1.
Ensure that operations are within
this geographic area.
SVS – SVS DISABLED: Terrain
DB resolution too low
SVS is disabled because a 9
Arc-Second or better database
is not currently loaded.
Ensure the P/N 010-00330-43
Terrain Cards are installed in the
lower slot of each display.
If terrain data has been recently
updated, ensure that the correct 9
Arc-Second databases were used.
5.2 GTS 820 Troubleshooting
Problem Cause Solution
Unit does not power up – Data
failed message
Improper wiring; circuit breaker
open
Ensure power is properly wired to
the GTS 820 and the circuit
breaker is closed
Improper configuration
Verify using the USB install tool
that the GTS 820 is configured
correctly for the desired display
GTS 8XX Install Tool won’t
display any pages
Improper wiring; circuit breaker
open
Ensure USB is properly wired to
the GTS 820 and the circuit
breaker is closed
No Audio alerts
Improper wiring; Volume not set
correctly
Ensure the audio is properly
wired from the GTS 820 and
volume is not set too low
Calibration Fault Factory calibration invalid
If the unit fails to go into operate
mode then return to Garmin for
service
Configuration Fault
Both internal and external
configuration checks failed
Verify the configuration via the
GTS 8XX Install Tool.
Verify wiring to the configuration
module and replace if necessary.
FPGA Fault Internal Fault Return to Garmin for service
ROM Fault Internal Fault Return to Garmin for service
Execution Fault Internal Fault Return to Garmin for service
Electrical Fault Internal Fault Return to Garmin for service
Whisper Shout Fault Internal Fault Return to Garmin for service
Transmit Power Fault
Internal voltages are out of
tolerance
Verify input voltage and if it
continues return to Garmin for
Seitenansicht 49