Page 4-6 G1000 System Maintenance Manual - Hawker Beechcraft G36
Rev. 5 190-01259-00
Pilot Compartment
• Top metal case of PFD: __________ milli-volts
• Top metal case of MFD: __________ milli-volts
• GTX 33 top: __________ milli-volts
• GIA 1 top: __________ milli-volts
• GIA 2 top: __________ milli-volts
• GMU metal base: __________ milli-volts
Ensure that at each PFD or MFD test point, no more than 20 milli-volts (20 mΩ) are present.
In this case, voltage is equivalent to resistance (Ω), given that precisely 1 amp reference
current is present. For all other LRUs see requirements below.
Cabin Compartment
• Metal case of GPA 65 LNA/PA: __________ milli-volts (part of GTS 820 option)
Empennage
• Metal case of GTS 820: __________ milli-volts (optional equipment)
Aircraft Exterior (Antennas)
• GA 58 Top traffic antenna mounting screw: __________ milli-volts (optional equipment)
• GA 58 Bottom traffic antenna mounting screw: __________ milli-volts (optional
equipment)
Ensure that at each test point, no more than 10 milli-volts (10 mΩ) are present. In this case,
voltage is equivalent to resistance (Ω), given that precisely 1 amp reference current is
present.
TIP: If 1 amp reference current cannot be maintained, note the difference between the
attainable current and 1 amp reference current. Calculate the percentage difference and
apply this to the voltage reading to obtain the equivalent resistance. Example: If the
measured current is 1.2 amps, (20% high from the target 1 amp current), then the allowable
voltage measurement would be 20% high, 2.5 milli-volts would now be 3.0 milli-volts.
If one or more bonding checks fails, i.e. the resistance is higher than those listed above,
then clean and rebond as necessary. Re-attach equipment racks/appliance/antenna and
complete electrical bonding test based on the original installation requirements. Refer to the
applicable installation drawing referenced in Table 1.1 for the bonding requirements.
After bonding checks are complete, ensure all electrical and coaxial cable connectors are
reconnected and all systems are working properly.