Garmin G1000 Cockpit Reference Guide for the Cessna Nav III
190-00384-13 Rev. B 7
Engine Indication System
Flight
Instruments EIS
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
Alerts Appendix Index
ENGINE DISPLAY
NOTE: Refer to the Pilot’s Operating Handbook (POH) for limitations.
The Engine Display is the default EIS display and can be displayed after viewing
other EIS displays by pressing the ENGINE Softkey.
EIS information is presented in three displays, accessed using the ENGINE Softkey
on the MFD.
The 172R, 172S, 182T, 206H, T182T, J182T (Engine and System Only), and
T206H display the following:
• Engine Display – Default display, shows all critical engine, fuel, and electrical
indicators
• Lean Display – Provides engine leaning information
• System Display – Shows numeric readouts of critical engine, fuel, and electrical
indicators
Green and white bands indicate normal ranges of operation; yellow and red bands
indicate caution and warning, respectively. If sensory data to an instrument becomes
invalid or unavailable, a red “X” is shown across the instrument.
ENGINE LEANING
NOTE: The pilot should follow the engine manufacturer’s recommended
leaning procedures in the Pilot’s Operating Handbook (POH).
The Lean Display is accessed by pressing the ENGINE Softkey followed by the
LEAN Softkey and provides information for performing engine leaning.
From the Lean Display, the pilot can utilize the CYL SLCT and ASSIST softkeys to
obtain information about specific cylinders. Pressing the CYL SLCT (Cylinder Select)
Softkey cycles through the cylinders (i.e., places a light blue box around the cylinder
number). This softkey is disabled when the ASSIST Softkey is pressed or when a
cylinder experiences a caution or warning condition; the softkey remains disabled
until the temperature returns to normal.
The ASSIST Softkey aids in the leaning process by identifying the peak of the first
cylinder whose temperature falls. If the temperature of the peaked cylinder exceeds
the peak value, the peak value is not updated. Press the ASSIST Softkey to stop peak
monitoring.