Garmin G1000 Cockpit Reference Guide for the Piper PA-44-180 Seminole
190-01462-01 Rev. A
94
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
Message Comments
MANIFEST
– GFC software
mismatch, communication halted.
Incorrect servo software is installed, or gain
settings are incorrect.
MANIFEST
– COM1 software
mismatch, communication halted.
The COM1 and/or COM2 has incorrect software
installed. The system should be serviced.
MANIFEST
– COM2 software
mismatch, communication halted.
MANIFEST
– NAV1 software
mismatch, communication halted.
The NAV1 and/or NAV2 has incorrect software
installed. The system should be serviced.
MANIFEST
– NAV2 software
mismatch, communication halted.
COM1 CONFIG
– COM1 config
error. Config service req’d..
The COM1 and/or COM2 configuration settings
do not match backup configuration memory. The
system should be serviced.
COM2 CONFIG
– COM2 config
error. Config service req’d.
COM1 TEMP
– COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The
transmitter is operating at reduced power. If the
problem persists, the system should be serviced.
COM2 TEMP
– COM2 over temp.
Reducing transmitter power.
COM1 SERVICE
– COM1 needs
service. Return unit for repair.
The system has detected a failure in COM1 and/
or COM2. COM1 and/or COM2 may still be
usable. The system should be serviced when
possible.
COM2 SERVICE
– COM2 needs
service. Return unit for repair.
COM1 PTT
– COM1 push-to-talk
key is stuck.
The COM1 and/or COM2 external push-to-talk
switch is stuck in the enable (or “pressed”)
position. Press the PTT switch again to cycle its
operation.
If the problem persists, the system should be
serviced.
COM2 PTT
– COM2 push-to-talk
key is stuck.
COM1 RMT XFR
– COM1 remote
transfer key is stuck.
The COM1 and/or COM2 transfer switch is stuck
in the enabled (or “pressed”) position. Press
the transfer switch again to cycle its operation.
If the problem persists, the system should be
serviced.
COM2 RMT XFR
– COM2 remote
transfer key is stuck.
Kommentare zu diesen Handbüchern