Garmin G1000 Cockpit Reference Guide for the Mooney M20M, M20R, & M20TN
190-00450-03 Rev. A
65
Annunciations & Alerts
Flight
Instruments EIS
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
Alerts Appendix Index
GIA 63 MESSAGE ADVISORIES
Message Comments
GIA1 CONFIG – GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do
not match backup configuration memory. The
G1000 system should be serviced.
GIA2 CONFIG – GIA2 config error.
Config service req’d.
GIA1 CONFIG – GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio
configuration. The G1000 system should be
serviced.
GIA2 CONFIG – GIA2 audio config
error. Config service req’d.
GIA1 COOLING – GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING – GIA2 temperature
too low.
GIA1 COOLING – GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the G1000 system should be
serviced.
GIA2 COOLING – GIA2 over
temperature.
GIA1 SERVICE – GIA1 needs service.
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a
problem in the unit. The G1000 system should
be serviced.
GIA2 SERVICE – GIA2 needs service.
Return the unit for repair.
MANIFEST – GIA1 software mismatch,
communication halted.
The GIA1 and/or GIA 2 has incorrect software
installed. The G1000 system should be serviced.
MANIFEST – GIA2 software mismatch,
communication halted.
COM1 TEMP – COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The transmit-
ter is operating at reduced power. If the problem
persists, the G1000 system should be serviced.
COM2 TEMP – COM2 over temp.
Reducing transmitter power.