Annunciations & Alerts
Flight
InstrumentsEAS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GMA 1347D MESSAGE ADVISORIES (CONT.)
Message Comments
GMA1 CONFIG
– GMA1 config
error. Config service req’d.
The audio panel configuration settings do not
match backup configuration memory. The
G1000 system should be serviced.
GMA2 CONFIG
– GMA2 config
error. Config service req’d.
MANIFEST – GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed. The
G1000 system should be serviced.
MANIFEST – GMA2 software
mismatch, communication halted.
GMA1 SERVICE – GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem in
the unit. Certain audio functions may still be avail-
able, and the audio panel may still be usable. The
G1000 system should be serviced when possible.
GMA2 SERVICE – GMA2 needs
service. Return unit for repair.
GIA 63W MESSAGE ADVISORIES
Message Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do
not match backup configuration memory. The
G1000 system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio
configuration. The G1000 system should be
serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1
temperature too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING
– GIA2
temperature too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the G1000 system should be
serviced.
GIA2 COOLING
– GIA2 over
temperature.