Garmin Software Version 0534.15 Betriebsanweisung Seite 92

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 122
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 91
Garmin G1000 Cockpit Reference Guide for the Cessna Corvalis/Corvalis TT
190-00567-04 Rev. A
76
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GMA 1347 MESSAGE ADVISORIES
Message Comments
GMA1 FAIL
– GMA1 is inoperative. The audio panel self-test has detected a failure.
The audio panel is unavailable. The G1000
system should be serviced.
GMA1 CONFIG
– GMA1 config
error. Config service req’d.
The audio panel configuration settings do not
match backup configuration memory. The
G1000 system should be serviced.
MANIFEST – GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed.
The G1000 system should be serviced.
GMA1 SERVICE – GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem
in the unit. Certain audio functions may still be
available, and the audio panel may still be usable.
The G1000 system should be serviced when pos-
sible.
GIA 63 MESSAGE ADVISORIES
Message Comments
GIA1 CONFIG – GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings
do not match backup configuration memory.
The G1000 system should be serviced.
GIA2 CONFIG – GIA2 config error.
Config service req’d.
GIA1 CONFIG – GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the
audio configuration. The G1000 system should
be serviced.
GIA2 CONFIG – GIA2 audio config
error. Config service req’d.
GIA1 COOLING – GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING – GIA2 temperature
too low.
GIA1 COOLING – GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the G1000 system should
be serviced.
GIA2 COOLING – GIA2 over
temperature.
Seitenansicht 91