Garmin G1000 Cockpit Reference Guide for the Beechcraft 58/G58
190-00526-01 Rev. B
63
Annunciations & Alerts
Flight
Instruments EIS
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
Alerts Appendix Index
GIA 63 MESSAGE ADVISORIES
Message Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do
not match backup configuration memory. The
G1000 system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the
audio configuration. The G1000 system should
be serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING
– GIA2 temperature
too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high.
If problem persists, the G1000 system should
be serviced.
GIA2 COOLING
– GIA2 over
temperature.
GIA1 SERVICE
– GIA1 needs service.
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a
problem in the unit. The G1000 system should
be serviced.
GIA2 SERVICE
– GIA2 needs service.
Return the unit for repair.
MANIFEST
– GIA1 software mismatch,
communication halted.
The GIA1 and/or GIA 2 has incorrect software
installed. The G1000 system should be
serviced.
MANIFEST
– GIA2 software mismatch,
communication halted.
COM1 TEMP
– COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The
transmitter is operating at reduced power. If
the problem persists, the G1000 system should
be serviced.
COM2 TEMP
– COM2 over temp.
Reducing transmitter power.
Seitenansicht 78